Free 溶接 Calculators — D1.1, D1.5, W59 適合 Tools

Clause5 provides 10 free compliance calculators covering 4 welding codes (D1.1, D1.5, D1.4, W59) with more than 800 reference pages of encoded standards. Each 計算機 returns the exact 基準 表, 条項 reference, and applicable 規格 so you can 確認 the 結果 directly.

Preheat Calculators

Preheat 温度 要求事項 vary by standard, steel grade, 溶接工程, and material 板厚. Each code uses a different lookup table with different input axes. Select the calculator for the code governing your project.

General Welding Calculators

These calculators apply across welding codes and are used during WPS development, production planning, and 溶接性 assessment. Heat input and 炭素当量 values feed directly into preheat requirements.

How to Use These Calculators

Every welding compliance calculation starts with identifying the governing code for your project. The code is specified in your 契約図書. For structural steel buildings in the United States, the governing code is AWS D1.1. For highway bridges, it is D1.5. For Canadian steel structures, CSA W59 applies. For pressure vessels and boilers, ASME Section IX governs (Clause5 does not currently cover ASME IX calculations).

Once you identify the code, select the matching 予熱計算機. Enter your steel grade (from your mill test report), welding process, and material thickness. The calculator returns the minimum 予熱温度 with the exact table reference. For quenched and tempered steels, also use the 入熱量計算機 to verify compliance with Clause 7.7 最大 heat input 限界値.

The 炭素当量計算機 serves two purposes: weldability assessment (higher CE means higher 割れ感受性) and alternative preheat determination under D1.1 Annex B when the full chemistry is available from the mill test report. The fillet weld size calculator ensures your WPS specifies at least the Table 7.7 minimum for the joint thickness.

The deposition rate calculator helps production planning by estimating metal deposited per hour based on wire feed speed, 電極 diameter, and process efficiency. This is critical for bidding, scheduling, and labor cost estimation. FCAW and GMAW processes deposit 2 to 5 times more metal per hour than SMAW, which directly impacts production timelines on multi-pass joints. Comparing deposition rates between processes helps fabricators select the most economical approach while maintaining code compliance.

Preheat Temperature and Why It Matters

Preheat is the minimum temperature the 母材 must reach before welding begins. Its purpose is to slow the 冷却速度 in the 熱影響部, allowing 拡散性水素 to escape before the 溶接金属 reaches temperatures where hydrogen-induced cracking can initiate. Higher-carbon steels, thicker material, and 非低水素 processes all increase 水素割れ risk and require higher preheat temperatures.

D1.1:2025 Table 5.11 assigns preheat based on three inputs: the steel grade (which determines the Table 5.6 group), the welding process and electrode hydrogen designation (which determines the preheat category A through G), and the material thickness. The intersection of these three inputs produces the minimum preheat temperature in degrees Fahrenheit. For bridge welding under D1.5, fracture-critical members add a fourth input: the heat input band. For rebar welding under D1.4, the input is carbon equivalent calculated from the mill test report chemistry, not steel grade.

Frequently Asked Questions

Start with the preheat calculator for your governing code. For structural steel in the United States, use the D1.1 preheat calculator (Table 5.11). For highway bridges, use D1.5. For reinforcing steel (rebar), use D1.4. For Canadian structural steel, use CSA W59. Heat input and carbon equivalent calculators apply across all codes.

Yes. All 10 calculators are free with no account required. Every result includes the governing code clause and table reference so you can verify the value directly against the standard.

The calculators cover AWS D1.1:2025 (Table 5.11 preheat, Table 7.7 fillet weld size, Annex B carbon equivalent), AWS D1.5:2025 (Tables 12.4 through 12.8 for fracture-critical preheat), AWS D1.4:2018 (Table 7.2 rebar preheat), and CSA W59:2018 (Table 5.3 preheat). Heat input and deposition rate use universal formulas.

Each calculator implements the exact lookup table or formula from the referenced standard. Preheat calculators return the same value you would get by reading the table manually. Results include the specific table number and clause reference for verification against the code edition specified in your contract documents.