AWS D1.1:2025 · Table 5.11 · Category C

A709 HPS70W Preheat for GMAW — 1-1/2" to 2-1/2"

Minimum preheat and interpass temperature for A709 HPS70W welded with GMAW at 1-1/2" to 2-1/2" thickness, per AWS D1.1:2025 Table 5.11.

Built on AWS D1.1:2025 Table 5.11 — every value traced to the clause.

Minimum Preheat & Interpass Temperature
225°F / 110°C
Category C Low-hydrogen SMAW, SAW, GMAW, or FCAW process (higher-strength steels)
AWS D1.1:2025 Table 5.11, §5.7
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

Have a preheat question? Ask Flux

GMAW (Gas Metal Arc Welding)

GMAW (MIG) feeds continuous solid wire with shielding gas — an inherently low-hydrogen process assigned to Category B in Table 5.11.

On high-strength plate, GMAW wire selection must meet the specified minimum tensile to satisfy weld metal matching. ER80S-D2 or ER100S-G wires serve higher-strength steels. The inherently low hydrogen input of solid wire makes GMAW particularly well-suited for crack-sensitive TMCP grades where minimizing diffusible hydrogen is the primary fabrication objective.

GMAW Tips for High-Strength and TMCP Steels

For A709 HPS70W (70 ksi yield, Category C, Q&T plate), GMAW requires higher-strength wire — ER80S-G or ER100S-G to achieve tensile matching at 70+ ksi weld strength. Note D1.1:2025 Table 5.11 sets both minimum AND maximum preheat/interpass for HPS70W: maximum 400°F up to 1-1/2", 450°F above. Exceeding the maximum interpass temperature risks over-tempering the Q&T microstructure.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Why GMAW for A709 HPS70W at 1-1/2" to 2-1/2"

Why GMAW for A709 HPS70W at 1-1/2" to 2-1/2"? GMAW delivers 8-12 lb/hr deposition — compared to SAW at 15-40 lb/hr. Position capability: all positions (not GMAW-S). Suitability: primarily shop.

A709 HPS70W

ASTM A709 HPS70W is the highest-strength weathering bridge steel with 70 ksi minimum yield and 85-110 ksi tensile range, used in long-span bridges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate in thicknesses up to 4", its high strength places it in Category C of Table 5.11 with correspondingly higher preheat requirements. Table 5.11 footnote (b) sets a maximum preheat/interpass of 400°F for thickness up to 1-1/2” and 450°F for thicker material — this upper limit is unusual in D1.1 and exists because the Q&T microstructure can be degraded by excessive heat. The chemistry includes copper (0.25-0.40%), nickel (0.65-1.00%), and chromium (0.40-0.65%) for atmospheric corrosion resistance, with 0.19% max carbon keeping the CE-IIW in the 0.46-0.52 range.

Why This Preheat for A709 HPS70W with GMAW

Highest-strength 70 ksi weathering bridge steel for long-span applications. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 225°F minimum with GMAW, the continuous solid wire and gas shielding in GMAW produce inherently low hydrogen levels, typically 2-4 mL/100g, but the preheat must still ensure the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material.

Typical Applications for A709 HPS70W

Reserved for long-span bridge main girder flanges, cable-stayed bridge edge girders, arch rib plates, high-load interchange ramp girders, and situations where reducing member depth saves clearance or reduces dead load. HPS70W enables weight savings of 20-30% versus conventional Gr.50 designs, allowing shallower girder sections that reduce embankment costs on grade-separation bridges. Flange thickness often exceeds 2”, making preheat and interpass control critical at every CJP splice and web-to-flange joint. Note that Table 5.11 footnote (b) sets maximum preheat and interpass limits of 400°F for thicknesses up to 1-1/2" and 450°F above. This upper limit is unusual in D1.1 and requires monitoring both minimum and maximum interpass throughout the welding sequence. Fabricators must use dual-readout temperature monitoring to ensure the joint stays within the qualified band. Filler metals must match the 70 ksi minimum tensile while providing weathering-compatible chemistry for exposed joints.

Why Preheat Matters at 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Category C Preheat for A709 HPS70W

Category C in Table 5.11 applies to higher-strength steels where the combination of hardenability and residual stress requires elevated preheat. For A709 HPS70W at 1-1/2" to 2-1/2", the 225°F minimum preheat slows the weld cooling rate to prevent formation of crack-susceptible martensite in the heat-affected zone. Maintaining interpass temperature at or above this minimum is especially critical for multi-pass welds on restrained joints.

Other Steels with GMAW at 1-1/2" to 2-1/2"

SteelCategoryPreheat
A36B150°F (65°C)
A53 Gr.BB150°F (65°C)
A106 Gr.BB150°F (65°C)
A633 Gr.EC225°F (110°C)

Try Different Combinations

Use the interactive preheat calculator to look up any steel, process, and thickness combination from D1.1:2025 Table 5.11.

What is the minimum preheat for A709 HPS70W with GMAW at 1-1/2" to 2-1/2"?
When welding A709 HPS70W at 1-1/2" to 2-1/2" using GMAW, the minimum preheat temperature is 225°F (110°C) per AWS D1.1:2025 Table 5.11, Category C. GMAW places this combination in Category C. This is also the minimum interpass temperature — the joint must not cool below 225°F between passes.
What Table 5.11 category applies to A709 HPS70W with GMAW?
When using GMAW on A709 HPS70W, the combination falls under Category C in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process (higher-strength steels). At 1-1/2" to 2-1/2" thickness, Category C with GMAW requires a minimum preheat of 225°F (110°C).
Why is preheat 225°F for A709 HPS70W at 1-1/2" to 2-1/2"?
The 225°F preheat for A709 HPS70W at 1-1/2" to 2-1/2" when using GMAW reflects the combination of the steel's hardenability and the increased restraint at this thickness. GMAW delivers controlled hydrogen levels, but at this thickness the preheat must slow the cooling rate in the heat-affected zone, giving diffusible hydrogen more time to escape before the steel transforms to a crack-susceptible microstructure.
What happens if I skip preheat on thick plate?
Without adequate preheat on material in the 1-1/2” to 2-1/2” range, the weld HAZ cools rapidly, trapping diffusible hydrogen in a hardened microstructure. This creates conditions for hydrogen-induced cracking (also called cold cracking or delayed cracking), which may not appear until hours or days after welding. Table 5.11 preheat minimums are set to prevent this failure mode.

D1.1:2025 reference data. Not affiliated with AWS.