AWS D1.1:2025 · Table 5.11 · Category C

A709 HPS70W Preheat for FCAW — up to 3/4"

Minimum preheat and interpass temperature for A709 HPS70W welded with FCAW at up to 3/4" thickness, per AWS D1.1:2025 Table 5.11.

Built on AWS D1.1:2025 Table 5.11 — every value traced to the clause.

Minimum Preheat & Interpass Temperature
50°F / 10°C
Category C Low-hydrogen SMAW, SAW, GMAW, or FCAW process (higher-strength steels)
AWS D1.1:2025 Table 5.11, §5.7
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

Have a preheat question? Ask Flux

FCAW (Flux Cored Arc Welding)

FCAW uses tubular flux-cored wire, available gas-shielded (E71T-1) or self-shielded (E71T-8) for field work. Category B in Table 5.11.

High-strength FCAW wires such as E81T1-K2 and E91T1-K2 provide tensile matching for Category C steels. The flux system in these wires is formulated for low diffusible hydrogen, often meeting H8 supplementary limits when tested per AWS A4.3. Wire storage requires climate-controlled conditions similar to SMAW electrodes to prevent moisture absorption.

FCAW Tips for High-Strength and TMCP Steels

For A709 HPS70W weathering bridge steel (70 ksi yield, Q&T plate, Category C), FCAW requires higher-strength weathering-compatible wire — E81T1-W2 or similar for both tensile matching and corrosion resistance on exposed joints. Category C minimum preheat: 50°F up to 3/4", stepping to 300°F above 2-1/2". Note: Table 5.11 also sets maximum interpass (400°F up to 1-1/2", 450°F above) to protect.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Filler Metal for FCAW

Gas-shielded: E71T-1C (AWS A5.20, requires 100% CO2) or E71T-1M (requires 75/25 Ar/CO2 mixed gas) — the C/M suffix designates the required shielding gas. Self-shielded: E71T-8 (no external gas, field-ready). Diameter: 0.045" standard, 1/16" for high-deposition. Stick-out: 3/4" to 1-1/4" (longer than GMAW due to resistive heating of flux core).

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

A709 HPS70W

ASTM A709 HPS70W is the highest-strength weathering bridge steel with 70 ksi minimum yield and 85-110 ksi tensile range, used in long-span bridges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate in thicknesses up to 4", its high strength places it in Category C of Table 5.11 with correspondingly higher preheat requirements. Table 5.11 footnote (b) sets a maximum preheat/interpass of 400°F for thickness up to 1-1/2” and 450°F for thicker material — this upper limit is unusual in D1.1 and exists because the Q&T microstructure can be degraded by excessive heat. The chemistry includes copper (0.25-0.40%), nickel (0.65-1.00%), and chromium (0.40-0.65%) for atmospheric corrosion resistance, with 0.19% max carbon keeping the CE-IIW in the 0.46-0.52 range.

Why This Preheat for A709 HPS70W with FCAW

Highest-strength 70 ksi weathering bridge steel for long-span applications. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 50°F minimum with FCAW, flux-cored wire in FCAW provides a combination of deoxidizers and low-moisture flux formulations that control hydrogen, but the preheat must still ensure the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material.

Typical Applications for A709 HPS70W

Reserved for long-span bridge main girder flanges, cable-stayed bridge edge girders, arch rib plates, high-load interchange ramp girders, and situations where reducing member depth saves clearance or reduces dead load. HPS70W enables weight savings of 20-30% versus conventional Gr.50 designs, allowing shallower girder sections that reduce embankment costs on grade-separation bridges. Flange thickness often exceeds 2”, making preheat and interpass control critical at every CJP splice and web-to-flange joint. Note that Table 5.11 footnote (b) sets maximum preheat and interpass limits of 400°F for thicknesses up to 1-1/2" and 450°F above. This upper limit is unusual in D1.1 and requires monitoring both minimum and maximum interpass throughout the welding sequence. Fabricators must use dual-readout temperature monitoring to ensure the joint stays within the qualified band. Filler metals must match the 70 ksi minimum tensile while providing weathering-compatible chemistry for exposed joints.

Why Preheat Matters at up to 3/4"

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

Category C Preheat for A709 HPS70W

Category C in Table 5.11 applies to higher-strength steels where the combination of hardenability and residual stress requires elevated preheat. For A709 HPS70W at up to 3/4", the 50°F minimum preheat slows the weld cooling rate to prevent formation of crack-susceptible martensite in the heat-affected zone. Maintaining interpass temperature at or above this minimum is especially critical for multi-pass welds on restrained joints.

Other Steels with FCAW at up to 3/4"

SteelCategoryPreheat
A36B32°F (0°C)
A53 Gr.BB32°F (0°C)
A106 Gr.BB32°F (0°C)
A633 Gr.EC50°F (10°C)

Try Different Combinations

Use the interactive preheat calculator to look up any steel, process, and thickness combination from D1.1:2025 Table 5.11.

What is the minimum preheat for A709 HPS70W with FCAW at up to 3/4"?
When welding A709 HPS70W at up to 3/4" using FCAW, the minimum preheat temperature is 50°F (10°C) per AWS D1.1:2025 Table 5.11, Category C. FCAW places this combination in Category C. This is also the minimum interpass temperature — the joint must not cool below 50°F between passes.
What Table 5.11 category applies to A709 HPS70W with FCAW?
When using FCAW on A709 HPS70W, the combination falls under Category C in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process (higher-strength steels). At up to 3/4" thickness, Category C with FCAW requires a minimum preheat of 50°F (10°C).

D1.1:2025 reference data. Not affiliated with AWS.