AWS ER70S-6 · WFS LookupCalculateur de vitesse de dévidage
Choisissez le diamètre du fil et saisissez l'intensité pour consulter les lignes publiées du mode opératoire Lincoln SuperArc L-56. Le résultat donne la vitesse de dévidage (ipm), la tension et le taux de fusion sous forme de plages face à l'enveloppe du fabricant. Périmètre : fil plein acier au carbone ER70S-6 ; seules les combinaisons gaz / mode de transfert publiées ; pas d'interpolation entre les lignes Lincoln.
Lincoln SuperArc L-56 (AWS A5.18 / ER70S-6) published operating-procedure rows for Acier au carbone Fil plein only. Short-Circuit Transfer assumes 100% CO2 shielding; Transfert par pulvérisation assumes 90% Ar / 10% CO2 shielding. Polarité is DC Électrode positive for all rows. Other gas blends, transfer modes, wire chemistries (stainless, aluminum, low-alloy, metal-cored, flux-cored), and base-metal alloys require their own vendor procedure tables.
Still have questions? Answers from 80 welding standards — with the clause number.
Comment fonctionne la plage encadrée
Le tableau Typical Operating Procedures du Lincoln SuperArc L-56 publie trois points de fonctionnement par diamètre de fil et mode de transfert. Chaque point est un tuple complet : vitesse de dévidage (ipm), tension (V), intensité (A) et taux de fusion (lb/hr). Si l'intensité tombe entre deux lignes publiées, le calculateur encadre la saisie et montre la plage de vitesse qui relie ces deux lignes. Si elle coïncide exactement avec une ligne, la plage se réduit à cette ligne.
Les modes opératoires de ces zones concernent le transfert par court-circuit avec 100 % de CO2. Avec 75 % d'argon et 25 % de CO2 en court-circuit, réduisez la tension de 1 à 2 volts.
Lincoln SuperArc L-56 Product Technical Data Sheet, Typical Operating Procedures Tableau footnote (6)
Ce calculateur n'extrapole pas au-delà de l'enveloppe publiée par Lincoln. Si l'intensité est inférieure à la plus petite valeur publiée pour le fil et le mode choisis, le résultat signale un hors plage et suggère un fil plus fin ou un autre mode de transfert. Si elle dépasse la plus grande valeur publiée, il suggère d'augmenter le diamètre. Travailler hors de l'enveloppe publiée, c'est opérer sans données de mode opératoire essayées par le fabricant ; consultez le DMOS de l'atelier ou l'assistance technique du fabricant du fil.
Citation de la source
This calculator's encoded values trace directly to the Lincoln SuperArc L-56 Product Technical Data Sheet, an AWS A5.18 / ER70S-6 carbon-steel solid wire. The Typical Operating Procedures table publishes 21 operating-point rows across 7 wire-diameter and transfer-mode combinations (0.030 SC, 0.035 SC, 0.035 SP, 0.045 SC, 0.045 SP, 0.052 SP, 1/16-in SP). All rows are encoded verbatim with per-row anti-fact tests pinning each value.
Document fingerprint — Published 2012-02-06; SHA256 b45ea7b8c8d1b59152a3907f8f91b29c53c29fdcef09ab931133a4dfb0d683a1; 247,322 bytes. Independently verified via two byte-identical Accueil Depot CDN mirrors of the same Lincoln document, confirming the procedure table has not been silently mutated since publication. A separate Lincoln content-delivery copy returned the same procedure-table values in a different document layout.
Wire conformance — Lincoln SuperArc L-56 conforms to AWS A5.18 and is classified as ER70S-6. AWS A5.18 specifies the chemistry and Minimum tensile / yield / elongation / impact values for the classification; vendor procedure tables like Lincoln's go beyond the Norme to publish typical operating points for shop use. Other ER70S-6 wires from other manufacturers will have similar but not identical operating envelopes. This calculator encodes Lincoln's specific published table; substituting a different ER70S-6 wire requires that manufacturer's own procedure data.
Trois lectures de référence
Vérifier your inputs against these reference lookups. All three use the encoded Lincoln SuperArc L-56 Typical Operating Procedures rows.
Example 1 — 0.035 wire, 175 A. Matches Lincoln's published Short-Circuit Transfer row for 0.035 in (0.9 mm) at 250 ipm / 22 V / 175 A / 4.0 lb/hr exactly. In-range badge: yes (Lincoln SC envelope for 0.035 wire is 80-175 A). The result card shows all three SC rows for 0.035 wire plus all three Spray Transfer rows (375-600 ipm / 195-275 A) so the user can see the full operating window for this wire diameter.
Example 2 — 0.045 wire, 310 A. Falls between Lincoln's published Spray Transfer rows for 0.045 in (1.1 mm) at 285 A (350 ipm) and 335 A (475 ipm). In-range badge: yes (Lincoln SP envelope for 0.045 wire is 285-340 A). WFS bracket: 350-475 ipm. The result card shows all three SP rows plus, for context, the three SC rows for the same wire (145-200 A, 125-200 ipm) so the user sees both transfer modes.
Example 3 — 0.062 wire, 500 A. Above Lincoln's published Spray Transfer envelope for 1/16 in (1.6 mm) wire, which caps at 430 A (290 ipm). Out-of-range badge with guidance to verify against shop WPS or contact Lincoln Applications Engineering. The result card still shows all three published rows so the user sees how far above the envelope they are.
Questions fréquentes
Autres outils de soudage
Lincoln SuperArc L-56 · AWS A5.18 / ER70S-6 · TDS published 2012-02-06