AASHTO/AWS D1.5:2025 · Tabla 12.8 · Fractura Crítica

Precal. HPS690W — 1.2–1.6 kJ/mm, 13–20 mm: 250–400°F

Requisito de precalentamiento de fractura crítica para M270M HPS690W / M270 HPS100W en espesor 13–20 mm (1/2–3/4 in), según AASHTO/AWS D1.5:2025, el Código de Soldadura de Puentes.

Basado en AWS D1.5:2025 — cada valor trazado a la cláusula.

Rango de Precalentamiento de Fractura Crítica
250–400°F / 120–200°C
Tabla 12.8 — aporte térmico 1.2–1.6 kJ/mm en espesor 13–20 mm (1/2–3/4 in)
AASHTO/AWS D1.5M/D1.5:2025 Tabla 12.8
Se deben mantener tanto el mínimo como el máximo de precalentamiento/interpaso. Exceder 400°F arriesga degradar la microestructura Q&T.
Herramienta de referencia. Verificar contra la edición aplicable al proyecto y WPS aprobada por el Ingeniero.

M270M HPS690W / M270 HPS100W

AASHTO M270M HPS690W (M270 HPS100W) is the highest-strength bridge steel at 690 MPa (100 ksi) yield, reserved for the most demanding long-span and cable-stayed bridge applications. It follows a completely different FC preheat table (Table 12.8) with min-max ranges and many prohibited thickness-heat input combinations marked with “—”. Table 12.8 requires H4 or H8 designated consumables; H16 is not permitted. NFC preheat per Table 6.3 Group 2; maximum interpass per Table 6.4 is 205°C (400°F) for material up to 40 mm, 230°C (450°F) above.

Dónde se Usa M270M HPS690W / M270 HPS100W

Reserved for the most demanding long-span and cable-stayed bridge applications where maximum weight reduction justifies the material cost premium and fabrication complexity. Table 12.8 imposes both minimum AND maximum preheat limits, and many thickness-heat input combinations are outright prohibited. Fabricators must plan weld procedures around the permitted combinations before cutting plate. Filler metals must carry the H4 or H8 supplemental designator — H16 is not permitted for HPS690W FC applications.

M270M HPS690W / M270 HPS100W en 13–20 mm (1/2–3/4 in)

HPS690W (HPS100W) at up to 20 mm is used in deck plate and stiffener components on orthotropic steel deck bridges — specialized long-span applications where the 100 ksi yield enables very thin plate to carry traffic loads. Table 12.8 requires both min and max preheat even at this thin section, and several heat input combinations are prohibited. Only H4 or H8 consumables are permitted; H16 is not allowed at any thickness.

Control de Precalentamiento Mín–Máx para M270M HPS690W / M270 HPS100W

Highest-strength 690 MPa (100 ksi) bridge steel with restricted FC combinations. Table 12.8 specifies a preheat RANGE of 250–400°F for this thickness and heat input combination. Unlike other FC grades, HPS690W requires both minimum AND maximum preheat control because the Q&T microstructure is sensitive to both excessive and insufficient heat. Many thickness-heat input combinations are prohibited ("—" in the table) because no safe preheat window exists — the steel cannot be reliably welded under those conditions.

Prueba Diferentes Combinaciones

Usa la Calculadora de Precalentamiento D1.5 para Puentes para consultar cualquier acero AASHTO M270, nivel de hidrógeno y combinación de aporte térmico. También consulta la Calculadora de Precalentamiento D1.1 para acero estructural.

¿Cuál es el rango de precalentamiento para HPS690W en 13–20 mm (1/2–3/4 in) con 1.2–1.6 kJ/mm?
La Tabla 12.8 de D1.5 requiere un rango de precalentamiento de 250–400°F (120–200°C) para HPS690W en 13–20 mm (1/2–3/4 in) con aporte térmico 1.2–1.6 kJ/mm. Se deben controlar tanto el mínimo como el máximo.
¿Por qué HPS690W tiene un límite máximo de precalentamiento?
HPS690W logra su resistencia de 690 MPa (100 ksi) mediante temple y revenido. Un precalentamiento excesivo puede ablandar la microestructura templada en la zona afectada por el calor. El límite máximo de 400°F (200°C) protege esta condición Q&T.

Datos de referencia D1.5:2025. Sin afiliación con AWS o AASHTO.